The LZR®-P110 is a universal safety solution for sliding, swing and revolving doors designed in conformity with the DIN 18650 and EN 16005 standards and a detection field of maximum 5 m x 5 m.

Description

Technology Laser scanner, time-of-flight measurement
Detection mode Presence
Max. detection range 5.0 m × 5.0 m
Uncovered zone 5 – 25 cm (adjustable)
Remission factor > 2 %
Angular resolution 0,3516 °
Min. detected object size (typ.) 2.1 cm @ 3 m ; 3.5 cm @ 5 m (in proportion to object distance)
Testbody 700 mm × 300 mm × 200 mm (Testbody CA according to EN16005/DIN18650)
Emission characteristics
IR Laser Wavelength 905nm; max. output pulse power 75W (Class 1)
Red visible Laser Wavelength 650nm; max. output CW power 3mW (Class 3R)
Supply voltage 10-35 V DC @ sensor side
Power consumption < 5 W
Peak current at power-on 1.8 A (max. 80 ms @ 35 V)
Response time typ 20 ms; max. 80 ms (+ output activation delay)
Output 2 electronic relays (galvanic isolated – polarity free)
Max. switching voltage 35 V DC / 24 V AC
Max. switching current 80 mA (resistiv)
Input 2 optocouplers (galvanic isolated – polarity free)
Max. contact voltage 30 V DC (over-voltage protected)
Voltage threshold Log. H: >8 V DC; Log. L: <3 V DC
Dimensions 125 mm (D) × 93 mm (W) × 70 mm (H) (Montagesockel + 14 mm)
Material PC/ASA
Colour Black or white
Rotation angles on bracket -5 ° to +5 ° (lockable)
Tilt angles on bracket -3 ° to +3 °
Protection degree IP65
Temperature range -30°C to +60°C if powered; -10°C to +60°C unpowered
Humidity 0-95% non-condensing
Vibrations < 2 G
Expected lifetime 20 years
Norm conformity EN 12978:2009; EN ISO 13849-1:2008 CAT2, Pl “d”; EN 60529:2001; IEC 60825-1:2007; EN 60950-1:2005; EN 61000-6-2:2005; EN 61000-6-3:2006; IEC 61496-1:2009; EN 61496-3:2008 ESPE Type 2; EN 62061:2005 SIL 2; EN 16005:2012 Chapter 4.6.8; DIN 18650-1:2010 Chapter 5.7.4; BS 7036-1:1996 Chapter 8.1

Reviews